APC/Schneider Electric Rack PDU 2G PN AP8858NA3

APC/Schneider Electric Rack PDU 2G PN AP8858NA3

$1,020.00

Ideal for colocation, large or remote data center operators
Plan capacity and balance loads with +/- 3% metering accuracy (amps, volts, kW, kWh)
Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity .
Real-time remote monitoring and management through EcoStruxure IT & Secure NMC3
Zero U toolless installation

Rack PDU 2G, Metered, ZeroU 20A 08V,(18)

SKU: AP8858NA3 Category: Brand:

Description

APC/Schneider Electric Rack PDU 2G PN AP8858NA3

APC NetShelter Metered Rack PDU, 2G, 0U, 20A, 208V, 18 C13 and 2 C19 outlets, L6-20 inlet

APC/Schneider Electric Rack PDU 2G PN AP8858NA3 provide active metering to enable energy optimization and circuit protection User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Specifications

Overview
Presentation APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Lead time Usually in Stock

Main
Color Black
Product or Component Type PDU
PDU Type Metered
Cord length 9.5 ft (2.9 m)
Number of cables 1
Provided Equipment Installation guide
Locking input power cord
Rack Mounting brackets
Serial configuration cable
Safety guide
Complementary
Input Voltage 200 V
208 V
230 V
240 V
Height 35.5 in (902 mm)
Width 2.2 in (56 mm)
Output Voltage 208 V
Depth 1.7 in (44 mm)
Net Weight 6.46 lb(US) (2.93 kg)
Mounting Location Side
Mounting preference No preference
Input Plug Type NEMA L6-20P
Mounting Mode Rack-mounted
Rack units 0U
Mounting position Vertical
Line Rated Current 16 A
Acceptable Input Voltage 100…240 V
Input current limits 20 A
Load Capacity 3300 VA
Input Frequency 50/60 Hz
Outlet type and quantity 18 IEC 60320 C13
2 IEC 60320 C19
Environment
Product Certifications METI Denan
VDE
Standards CSA C22.2 No. 60950
IEC 60950
UL 60950-1
Ambient air temperature for operation 23…140 °F (-5…60 °C)
Relative Humidity 5…95 %
Operating altitude 0…10000 ft
Ambient Air Temperature for Storage -13…149 °F (-25…65 °C)
Storage Relative Humidity 5…95 %
Storage altitude 0…50000 ft (0…15240 m)
Ordering and shipping details
GTIN 731304277040
Country of origin IN
Packing Units
Unit Type of Package 1 PCE
Nbr. of units in pkg. 1
Package 1 Height 44.3 in (112.4 cm)
Package 1 Width 4.2 in (10.7 cm)
Package 1 Length 6.4 in (16.2 cm)
Package weight(Lbs) 10.85 lb(US) (4.92 kg)
Contractual warranty
Warranty 2 years repair or replace

Specs

Videos

Additional information

Weight 11 lbs
Dimensions 4.9 × 6.7 × 44 in

Reviews

There are no reviews yet.

Be the first to review “APC/Schneider Electric Rack PDU 2G PN AP8858NA3”

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Go to Top