APC/Schneider Electric PDU 2G PN AP8862

APC/Schneider Electric PDU 2G PN AP8862

$1,290.00

Ideal for network and server closets or distributed IT sites
Plan capacity and balance loads with +/- 3% metering accuracy (amps, volts, kW, kWh)
Real-time remote monitoring of connected load through EcoStruxure IT and other platforms
Stay on top by defining alarm thresholds in order to avoid overloaded circuits
0U design maximizes usable rack space for IT equipment

PDU 2G, Metered, ZeroU,20A, 208V 3P

Description

APC/Schneider Electric PDU 2G PN AP8862

APC NetShelter Metered Rack PDU, 2G, 0U, 20A,120/208V, 3 phase, 36 NEMA 5-20R outlets

APC/Schneider Electric PDU 2G PN AP8862 provide active metering to enable energy optimization and circuit protection User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Specifications

Overview
Presentation APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Lead time Usually in Stock
Main
Color Black
Product or Component Type PDU
PDU Type Metered
Cord length 5.97 ft (1.82 m)
Number of cables 1
Provided Equipment Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide
Complementary
Input Voltage 208 V 3 phase
Height 70.5 in (1791 mm)
Width 2.2 in (56 mm)
Output Voltage 120 V
Depth 1.7 in (44 mm)
Net Weight 13.32 lb(US) (6.04 kg)
Mounting Location Side
Mounting preference No preference
Input Plug Type NEMA L21-20P
Mounting Mode Rack-mounted
Rack units 0U
Mounting position Vertical
Line Rated Current 16 A
Input current limits 20 A
Load Capacity 5760 VA
Input Frequency 50/60 Hz
Outlet type and quantity 36 NEMA 5-20R
Environment
Product Certifications cUL Listed
UL Listed
Standards FCC Part 15 class A
ICES-003
UL 60950-1
Ambient air temperature for operation 23…140 °F (-5…60 °C)
Relative Humidity 5…95 %
Operating altitude 0…10000 ft
Ambient Air Temperature for Storage -13…149 °F (-25…65 °C)
Storage Relative Humidity 5…95 %
Storage altitude 0…50000 ft (0…15240 m)
Ordering and shipping details
GTIN 731304307488
Country of origin IN
Packing Units
Unit Type of Package 1 PCE
Nbr. of units in pkg. 1
Package 1 Height 79.0 in (200.6 cm)
Package 1 Width 4.26 in (10.83 cm)
Package 1 Length 6.48 in (16.47 cm)
Package weight(Lbs) 17.90 lb(US) (8.12 kg)
Contractual warranty
Warranty 2 years repair or replace

Specs

Videos

Additional information

Weight 17 lbs
Dimensions 79 × 6.8 × 4 in