APC/Schneider Electric Rack PDU 2G PN AP8870

APC/Schneider Electric Rack PDU 2G PN AP8870

$1,455.00

Ideal for colocation, large or remote data center operators
Plan capacity and balance loads with +/- 3% metering accuracy (amps, volts, kW, kWh)
Historical reporting enables users to meter customer power usage, optimize energy use as well as plan for capacity .
Real-time remote monitoring and management through EcoStruxure IT & Secure NMC3
Zero U toolless installation

Rack PDU 2G, Metered, ZeroU,

Description

APC/Schneider Electric Rack PDU 2G PN AP8870

APC NetShelter Metered Rack PDU, 2G, 0U, 30A, 100-120/200-240V, 16 NEMA 5-20R, 12 C13, 2 C19 outlets

APC/Schneider Electric Rack PDU 2G PN AP8870 provide active metering to enable energy optimization and circuit protection User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.

Specifications

Overview
Presentation APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Lead time Usually in Stock
Main
Color Black
Product or Component Type PDU
PDU Type Metered
Other Output Voltage 240 V
Cord length 9.5 ft (2.9 m)
Number of cables 1
Provided Equipment Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide
Complementary
Input Voltage 120 V
208 V
Height 70.5 in (1791 mm)
Width 2.2 in (55 mm)
Output Voltage 120 V
Depth 1.7 in (44 mm)
Net Weight 14.07 lb(US) (6.38 kg)
Mounting Location Side
Mounting preference No preference
Input Plug Type NEMA L14-30P
Mounting Mode Rack-mounted
Rack units 0U
Mounting position Vertical
Line Rated Current 24 A
Input current limits 30 A
Load Capacity 4992 VA
Input Frequency 50/60 Hz
Outlet type and quantity 16 NEMA 5-20R
12 IEC 60320 C13
2 IEC 60320 C19
Environment
Product Certifications cUL Listed
UL Listed
Standards FCC Part 15 class A
ICES-003
UL 60950-1
Ambient air temperature for operation 23…140 °F (-5…60 °C)
Relative Humidity 5…95 %
Operating altitude 0…10000 ft
Ambient Air Temperature for Storage -13…149 °F (-25…65 °C)
Storage Relative Humidity 5…95 %
Storage altitude 0…50000 ft (0…15240 m)
Ordering and shipping details
GTIN 731304307501
Country of origin IN
Packing Units
Unit Type of Package 1 PCE
Nbr. of units in pkg. 1
Package 1 Height 79.0 in (200.6 cm)
Package 1 Width 4.26 in (10.83 cm)
Package 1 Length 6.48 in (16.47 cm)
Package weight(Lbs) 15.85 lb(US) (7.19 kg)
Contractual warranty
Warranty 2 years repair or replace

Specs

Videos

Additional information

Weight 20 lbs
Dimensions 79 × 6.12 × 4.02 in