APC/Schneider Electric Rack PDU 2G PN AP8632
APC Rack PDU, 2G, metered by outlet, with switching, 0U, 30A, 100V to 120V, 24 NEMA 5-20R sockets
APC/Schneider Electric Rack PDU 2G PN AP8632 enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules.
Specifications
Overview
| Presentation |
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering. Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by Struxureware for Data Centers using Data Center Expert and Data Center Operations with Capacity and Change modules. |
| Lead time |
Usually in Stock |
Main
| Color |
Black |
| Product or Component Type |
PDU |
| PDU Type |
Metered outlet |
| Cord length |
9.5 ft (2.9 m) |
| Number of cables |
1 |
| Provided Equipment |
Installation guide
Rack Mounting brackets
Serial configuration cable
Safety guide |
Complementary
| Input Voltage |
100 V
120 V |
| Height |
72.008 in (1829 mm) |
| Width |
2.2 in (55 mm) |
| Output Voltage |
100 V
120 V |
| Depth |
2.008 in (51 mm) |
| Net Weight |
17.75 lb(US) (8.05 kg) |
| Mounting Location |
Side |
| Mounting preference |
No preference |
| Input Plug Type |
NEMA L5-30P |
| Mounting Mode |
Rack-mounted |
| Rack units |
0U |
| Mounting position |
Vertical |
| Line Rated Current |
24 A |
| Acceptable Input Voltage |
100…120 V |
| Input current limits |
30 A |
| Load Capacity |
2880 VA |
| Input Frequency |
50/60 Hz |
| Outlet type and quantity |
24 NEMA 5-20R |
Environment
| Product Certifications |
cUL Listed
PSE
UL Listed |
| Standards |
FCC Part 15 class A
ICES-003
UL 60950-1 |
| Ambient air temperature for operation |
23…140 °F (-5…60 °C) |
| Relative Humidity |
5…95 % |
| Operating altitude |
0…10000 ft |
| Ambient Air Temperature for Storage |
-13…149 °F (-25…65 °C) |
| Storage Relative Humidity |
5…95 % |
| Storage altitude |
0…50000 ft (0…15240 m) |
Ordering and shipping details
| GTIN |
731304307457 |
Packing Units
| Unit Type of Package 1 |
PCE |
| Nbr. of units in pkg. |
1 |
| Package 1 Height |
80.4 in (204.1 cm) |
| Package 1 Width |
4.69 in (11.92 cm) |
| Package 1 Length |
6.48 in (16.47 cm) |
| Package weight(Lbs) |
22.33 lb(US) (10.13 kg) |
Contractual warranty
| Warranty |
2 years repair or replace |